Pulse oximeter - finger pulse oximeter - contec medical systems Comapny Ltd
Inquire Now | Add to Inquiry Cart | Trade Leads
Home | Company Profile | Catalog List
 
Cms800F maternal fetal doppler Inquire now
 

Product Description
Features:

■ Single or Twins Ultrasound transducer
■ Data Graph and Trend Table Review of both mother and fetal
■ Built-in thermal printer
■ Built-in Network capability for connect with central monitoring software■ Programmable alarms
■ All the colors and looks or the parameters can be customsized
■ Multi-face views, select focus on mother or fetal■ Storage of patient information and data

Performance Specifications:
■ Display:8.4" Color TFT
■ Resolution:640x480
■ Display Mode:Standard View,Fetal View,Mother View
■ Indicator:Power indicator light, Alarm sound
■ Interface:Socket for connecting fetal's FHR, TOCO, and
Fetal Movement sensorSocket for connecting mother's ECG,

NIBP and SPO2 sensor.

Net Socket(RJ45) for communication cable with

Central Monitoring Station Sofrware.

■ Power Supply:AC 100 ~ 240V, 50/60Hz, Powe < 60VA■ Trend Graph:Resolution from 1s, 5s, 10s. Maximum time 96 hours.■ Trend Table:Resolution from 1s, 5s, 10s. Review up to 1000 items.■ Alarm:Ajustable High and Low limits. Three level audible and vistual alarm.
■ User Configuration:All the color of parameters and waves
can be set according to user's willing.

Technical specifications:

■ Safety
■ Meet the requirment of IEC60601 series
■ Type of Protection:Class II with internal electirc power supply
■ Degree of Protection:BF
■ Dimention and Weight
■ Dimention:92(W)x82(H)x22(D)mm
■ Weight:136g(with battery)
■ Operation Environment:
■ Temperature:0℃~ +40℃
■ Humidity:15% ~ 95%
■ Storage Environment:
■ Temperature:-20℃~ +60℃
■ Humidity:10% ~ 95%
■ Patient Range:Pregnant Adult

FHR:

■ Ultrasound Frequency:2MHz
■ Range:50 ~ 210 bpm
■ Resolution:1bmp
■ Accuracy:±2bmp

TOCO:

■ Range:0 ~ 100%
■ Resolution:1%
■ Non-linear Error:<=±8%
■ Zero control:Manual

FETAL MOVEMENT:

■ Manual fetal movement mark

SPO2:

■ Measurement Range:0 ~ 100%
■ Resolution:1%
■ Accuracy:±2%(70%~100%, Adult/Pediatric, non-motion)±3%(70% n

~100%, Neonate, non- motion)0% ~ 69% unspecified

■ Alarm Range:0% ~ 100%
■ Refreshing Rate:1s

Pulse Rate:

■ Measurement Range:25 ~ 250 bpm
■ Resolution:1bpm
■ Accuracy:±3 bpm (non-motion)
■ Alarm Range:25 ~ 250 bmp
■ Refreshing Rate:1s

ECG:

■ Lead mode:3-lead or 5-lead
■ Lead selection:I, II, III, AVR, AVL, AVF, V
■ HR range:15 ~ 300 bpm
■ ECG Waveform:2 channals
■ Accuracy:±2bpm or ±2%, which is greater
■ S-T segment detection range: -2.0mv ~ +2.0mv■ Arrhythmia analysis: 13 kinds of arrhythmia
■ Alarm Range:15 ~ 300 bpm

NIBP:

■ Method:Oscillometry
■ Mode:Manual/Auto/Contiuous
■ Measurement Range:25 ~ 260mmHg■ Atuo Measure Interval: 5, 10, 15, 30, 45, 60, 90 minutes
■ Resolution:1mmHg
■ Overpressure Protection: 300mmHg
■ Alarm range:25 ~260mmHg




Price Terms︰ Fob Beijing
Payment Terms︰ T/T
Packing︰ BOX
Lead Time︰ 5 DAYS
Standards Certificate︰ CE
Way for payment︰ Paypal Bank wire transfer

Payment
T/T Paypal

Delivery
30 days

Origin
China

Minimum Order
5

Packaging
box

Samples
Charge


Contact Information
 
Pulse oximeter - finger pulse oximeter - contec medical systems Comapny Ltd
#24 West Yellow Rd
Qinghuangdao, Hebei
China 066004
  • Tel : 86-335-8015-415
  • Fax : 86-335-8015-590
  • Homepage : http://www.contec-oximeter.com

    Contact :
    Mr. richard chang
    manager, Sales

  • inquire now

     
    Home | Company Profile | Catalog List
    Inquire Now | Add to Inquiry Cart | Trade Leads

    Powered by EC Plaza
    Home | Buy Now | Sell Now | My Trade Office | Biz Support | Trade Mall | PR News
    Created by the "Home Page Generator" A free service of EC PLAZA
    Visitors:  040917